Formlabs High Temp Resin 3D Printing Material

Formlabs High Temp resin is an SLA material for detailed parts exposed to heat with minimal loading

Formlabs High Temp Resin Material

What is Formlabs High Temp Resin?

Formlabs High Temp resin is an SLA material for detailed parts exposed to heat with minimal loading. Its heat deflection temperature at 0.45 MPa is 120 °C (248 °F) after the specified post-cure, rising to 238 °C (460 °F) with an additional thermal cure. These are test values under defined conditions, rather than continuous operating temperatures.

Formlabs High Temp Resin Overview


Applications

Formlabs High Temp resin’s thermal stability makes it suitable for prototypes and tooling exposed to elevated temperatures. Typical applications include hot-air and fluid-flow test components, heat-resistant mounts, and mould inserts.

Key Product Benefits

  • High heat resistance after post-curing
  • High stiffness

Tolerances

For well-designed parts, dimensional accuracy of ±0.3% of the nominal dimension, with a minimum tolerance of ±0.3 mm (±0.012 in.), can typically be achieved. Tolerances may vary depending on part geometry.


Formlabs High Temp Properties


Property Test Method Metric Value Imperial Value
Ultimate tensile strength* ASTM D638-14 49 MPa ≈7,110 psi
Tensile modulus* ASTM D638-14 2.8 GPa ≈406 ksi
Elongation at break* ASTM D638-14 2.3% 2.3%
Flexural strength at break* ASTM D790-15 97 MPa ≈14,100 psi
Flexural modulus* ASTM D790-15 2.8 GPa ≈406 ksi
Notched Izod impact strength* ASTM D256-10 17 J/m ≈0.32 ft·lbf/in
HDT at 1.8 MPa (≈261 psi)* ASTM D648-16 101 °C 214 °F
HDT at 0.45 MPa (≈65.3 psi)*  ASTM D648-16 238 °C 460 °F
HDT at 0.45 MPa (≈65.3 psi), standard post-cure ASTM D648-16 120 °C 248 °F
Data sheet Download data sheet (PDF)

Values are based on manufacturer testing and are approximate. Actual part properties may vary with geometry, machine settings, and processing conditions. This information is not binding and is not deemed to be certified. When performance is critical, consider independent laboratory testing of the material or finished part.
*Starred values follow a 120-minute post-cure at 80 °C plus a 180-minute thermal cure at 160 °C. The final row follows a 60-minute post-cure at 60 °C.